Explore the proposed lab
The current plan for the Cy4CEA lab at the ISU Research Park. Turn the 3D model, see what goes where, and how a robot moves a crop.
Under consideration and subject to change. This is concept geometry, not a survey. Layout, equipment and numbers will change as the plan is reviewed.
Turn the model
Drag to rotate, scroll or pinch to zoom, right-drag to pan. Pick a view, or play the cassette transfer.
What goes where
Water and crops on the west and north, dry work on the east and south, robots in the middle. Drains, taps, the sink and doors stay where they are.

| Zone | Where and why |
|---|---|
| NFT, 36 experiments | Two existing racks, loaded from both sides, ends at the water wall |
| Robot floor | 18 pots in a grid with a lane all round, so a robot can circle each one |
| Mung and saffron | Pallet racks on the north side, by the sink and tap |
| Planting and harvest | Planting table by the sink; harvest tables in the centre by a drain |
| Robotics and demos | Dry east side, where visitors can watch robot arms being built |
| Entry room | Lockers and desks, with a window into the lab |
How a cassette comes out
Each experiment grows in a cassette. A rolling lift brings it down to bench height for imaging and care.

- Raise the lift deck to the tier and latch it to the rack.
- The cassette's pump stops and its channels drain.
- Hook a strap to the cassette and turn the crank. The cassette slides onto the deck. It carries no plumbing, so nothing is unlatched.
- Lower it to bench height. No hoses to reconnect.
- To return it, raise the deck and push it back until it latches.
Water and nutrients
- Every cassette is its own experiment, with its own tank, pump, probes and dosing pumps. That gives 36 separate nutrient loops.
- Fixed nozzles drop water into the channels across a small air gap. Nothing connects to the cassette.
- Channels drain by gravity back to the same tank. No loop shares water with another.
- Stock jugs for nutrient A, B, pH down and pH up sit in a spill tray at each bay.
- Cassettes sit back to back in pairs. Each pair shares its light bars and fans.
- A drip pan under each upper cassette returns any leak to its own tank.

The parts, close up
Rendered from the same model. Click a picture to enlarge it.









Control, built for AI agents
An agent can read data and change setpoints, recipes and schedules inside set limits. It never drives a pump directly.
- Each cassette has pH, EC and temperature probes, dosing pumps, a flow sensor and level switches.
- A control panel at each bay wires up its six loops.
- One lab computer holds all the control logic. It sends each part a simple signal: on or off, open or shut, up or down.
- A controller at each bay passes those signals on. If the lab computer goes silent, it shuts the valves and keeps the pumps running.
- Each pair sets its own light height and can be blacked out for day-length studies.
- In a power cut, batteries keep the pumps cycling for about a day.
- Every pump has a hand switch that works with the controller off.
One cassette, one loop
Thirty-six identical loops. Nothing is shared between them except clean water in and waste out.
- A covered tank under the rack holds about 12.5 gallons for 16 plants.
- A low-voltage pump lifts about 4 litres a minute to the cassette.
- Four fixed nozzles drop 1 litre a minute into each channel across a small air gap.
- The film runs down a 1 in 40 slope over 32 inches and returns to the same tank.
- Clean water arrives through two valves in series, so one stuck valve cannot flood the floor.
- Reverse osmosis water is the planned base, so every recipe starts from the same water.
What an experiment can vary
Thirty-six loops give twelve nutrient treatments in triplicate. Light and air are set per pair of cassettes.
| Factor | Set per | Independent units | How |
|---|---|---|---|
| Nutrient strength and pH | Cassette | 36 | Dosing pumps hold a conductivity and a pH target |
| Ratio of the two nutrient stocks | Cassette | 36 | The two dosing pumps run in a set ratio |
| The stock solutions themselves | Bay of six cassettes | 6 | Each bay has its own jugs |
| Flow rate | Cassette | 36 | Pump speed |
| Crop or cultivar | Cassette | 36 | |
| Day length and light level | Pair | 18 | Switching and dimming |
| Air speed over the leaves | Pair | 18 | Fan speed |
| Air temperature, humidity, CO₂ | Room | 1 | Measured in every bay, not controlled per unit |
Plant numbers and border rows
Channels are grouped in fours so that some plants have a neighbour on every side.
- Each cassette holds 16 plants at 8 inch spacing, 576 in the lab.
- A study that needs more interior plants runs a pair as one plot, and halves its treatments.
- Each tier has its own light bars 15 inches above the channels, so no tier shades another.
- Expected light at full power is about 220 µmol/m²/s. It will be measured on the first pair.
What is measured
Every reading is stored with a time stamp and the cassette's crop and treatment labels.
| Where | Measured | How often |
|---|---|---|
| Each tank | pH, conductivity, solution temperature, low and high level | Every 10 seconds |
| Each cassette feed | Flow | Continuous |
| Each cassette side | Air temperature and humidity | Every 10 seconds |
| Each pair | Light on, fan running | Continuous |
| Each bay | CO₂, leak | Every 10 seconds |
| Each rack | Water added to each tank, which is the plants' uptake | Per fill |
| Any cassette | Colour and near-infrared images | One shared camera, on request |
| Each cassette return | An open port for a reference probe or a trial sensor | When fitted |
Built to fail safely
What happens when something goes wrong.
| If this happens | The design does this |
|---|---|
| A pump stops | A flow alarm within two minutes. Only one cassette is affected. Every pump has a hand switch that works with the controller off. |
| A leak at a tier | A pan under each upper cassette returns the water to its own tank. A tray under the tanks holds a leak sensor that shuts the fill valves. |
| A fill valve sticks open | A float valve behind it closes. A level switch and a time limit close a second valve on the rack. |
| The power fails | Lights and fans go off. Batteries keep every pump cycling for about a day. |
| The network or a computer stops | Each bay controller notices within 10 seconds, shuts its valves and keeps the water moving. |
| A dosing error | Dose limits sit in the controller, outside the software an agent can reach. |
| Root disease in one loop | No loop shares solution with another, and the feed crosses an air gap. |
| A rack is pulled or pushed | Levelling feet replace the casters, and each rack is pull-tested before use. |
The cassette
A frame of aluminium extrusion carries four channels. It slides out to the aisle and carries no plumbing and no wiring.
How a bay goes together
A bay is the unit that is built, tested and repeated. Each picture is the same cut through a bay. Parts added at that stage are amber.
Light height and blackout
Each pair sets its own light height and its own day length. One motor moves the light frame. Two motor blinds close the pair.
| The computer sends | The part does the rest |
|---|---|
| Light frame up, light frame down | The tube motor winds or unwinds four cords. Its own end stops halt it at the top and bottom. |
| South blind up, down. North blind up, down | The motor in each roll runs to its own end stop. |
| Lights on or off, dim level | As before: one relay signal and one 0-10 V level per pair. |
- Before a cassette is pulled, the computer raises the light frame and that face blind. It releases the pull only when both report up.
- A blind goes down only when both cassettes of the pair read seated.
- The frame stops at the height the plant scientist sets for that crop. The low limit is 6 in above the channels.
- In a dark period the computer closes both blinds, turns the pair lights off and keeps the fans running.
- If the computer goes silent, nothing moves. Frames and blinds hold where they are.
Built in phases
Each phase ends with a lab that works. If funding stops, the build stops at the end of a phase.
| Phase | What is built | What works at the end |
|---|---|---|
| 1. One pair | Two cassettes at tier 3 of bay A1 with everything: loops, light lift, blinds, bay panel, lab computer. Rack rework, stairs and the light meter. | Two cassettes grow a crop under full control. Filled and drained by hose. Every design risk has been tested. |
| 2. Bay A1 | The other four loops and cassettes of bay A1. | Six independent loops. Enough for one small replicated trial. |
| 3. Water, drain and battery | Supply header, reverse osmosis, drain line, new circuits, three batteries, backflow preventer. | Bay A1 fills and drains itself and rides through a power cut. The room is ready for more bays. |
| 4. Rack A | Bays A2, A3 and A4 with their cassettes. | 24 loops on one rack. Four replicates of six treatments. |
| 5. Rack B | Bays B1 and B2 with their cassettes, and the spare pumps. | All 36 loops. The grow system is complete. |
| 6. Lift and instruments | Mast lift, pull winch, shared camera, reference meters. | One person can pull a tier 3 cassette. Until now that takes two people on the rolling stairs. |
| 7. The rest of the room | Robot lockers, cage, benches, cameras, server cabinet, vine bay. | The pot rows, the vine bay and the robot areas are fitted out. |
| 8. Blackout on the other 17 pairs | Blinds, panels, vents and switches for every pair after the first. | Any pair can run its own day length. Before this, only the first pair can. |
Build documents
Everything needed to order, build and test the lab. Prices are estimates and change with each revision.
- WorkplanEvery step to set up the lab, in order, with tick boxes.
- Assembly guideHow one bay goes together, part by part, and what is kept from the present lab.
- Cassette drawingShop drawing of one cassette, with cut list, hardware and checks.
- LatchHow a cassette latches and releases, the parts, and where to buy them.
- Build specThe full specification: findings, each system, power, control and the priced order list.
- Design reviewA short summary for reviewers, with the open questions.
- Water loopHow water goes into and out of one cassette, state by state, and which way a cassette pulls out.
- Lights and fansHow the light frame and its two fans move up and down, dim, and go dark, pair by pair.
- Order list (spreadsheet)Every line to buy, by wave, with part numbers and sellers.
Animations
Rendered from an earlier version of the model. Updated clips are in progress.
Views









Still open
Ceiling height above the racks, the light fixtures and their power, structural and Facilities sign-off, and vendor quotes. The plan will change as these are settled.
Work with us