Cy4CEA grow lab · build spec revision E · 24 Nov 2026
How water moves through one cassette
Each of the 36 cassettes has its own tank, pump and probes. Water is pumped up, dropped into the channels across an air gap, and falls back by gravity. The cassette itself carries no plumbing, so it slides out with nothing to unhook.
Pumped nutrientGravity returnClean RO water inDosingDrain out
One loop, tier 3 cassette. Pick a state.
The path, in the order the water takes it
1Tank to pumpOne ¾ in bulkhead, 1½ in above the tank floor at the spine end. Then a ball valve, a 50 mesh strainer and a union. The pump sits below the water line, so it is always flooded.
2PumpLaing D5 Strong, 24 V wet rotor. A step-down module sets its voltage, and so its flow. Unions on both sides let it come out in minutes. No brass anywhere in the nutrient line.
3TeeOne leg goes up the riser. The other goes to the motorised drain valve. The same pump feeds the cassette and empties the tank.
4Riser and flow sensor½ in schedule 40 PVC up the spine. No branches: one riser feeds one cassette. A Hall flow sensor on each feed proves the water is moving.
5Nozzle railA small rail fixed to the rack frame above the high end of the channels. Four ¼ in tubes leave it, all cut to 24 in. Equal lengths share the flow evenly, about 1 L/min each.
6Air gap at the inletEach nozzle tip sits ½ in above the channel cap, inside a 1 in collar round a ¾ in hole, 2 in from the sealed high end. The stream never touches the cassette and never falls through open air.
7Channel32 in long, sloped 0.8 in (1 in 40) by two shims, ¾ in and ⅜ in, on a level frame. A thin film runs past four plants at 8 in centres.
8Collector and troughThe open low end reaches ½ in over a gutter 1½ in wide and 2 in deep. The gutter falls toward the spine and spouts into this cassette's own trough. A plugged ¾ in sensor port at the outlet reads the solution as it leaves the roots.
9Downpipe home1½ in pipe straight down to this cassette's tank cover. A mesh sock on the outlet catches roots. The two cassettes of a pair never share a trough or a pipe.
Schematic, not to scale. Left and right are spread out so every part can be seen. In the rack, the pump, riser, trough and downpipe all sit at the spine end of the tank, in a 10 in gap between the north and south tank rows.
The cassette from above
Four streams go in at the high end and come together in one collector at the low end. Nothing on the cassette is a fitting. The rail and nozzles belong to the rack.
Pull direction. The channels run parallel to the aisle. The cassette slides at right angles to them: out toward the aisle by its grip bar, and in toward the spine until the latch clicks. The nozzles sit over the high end, so they stay put while the channels slide out from under them, sideways.
Why the pump is sized as it is
Head the pump must give for a tier 3 cassette, at 4 L/min.
Item
Head
Lift to the tier 3 channel inlet
6.6 ft
Suction valve, strainer, unions
1.0 ft
Riser, ½ in PVC, 15 ft with fittings
0.2 ft
Flow sensor and run to the rail
0.5 ft
Four ¼ in tubes, 24 in, 1 L/min each
0.9 ft
Coupling (removed in revision C)
0 ft
Margin
1.5 ft
Pump duty
11 ft at 4 L/min
The D5 Strong curve gives about 14 L/min at 13 ft, so it runs below full voltage. Tiers 1 and 2 need about 6 and 8 ft. Turn each pump down until its cassette reads 4 L/min. Pond pumps at the old price stop at 11.6 to 13.5 ft and could not reach tier 3.
Design values
Flow per channel
1.0 L/min (0.5 to 1.5)
Flow per loop
4 L/min
Channel slope
1 in 40
Plants per loop
16
Tank working volume
12.5 gal at 10 in
Time for one full pass of the tank*
about 12 min
Low / high level switch
4 in / 11 in
Float valve closes
10 in
Flow alarm
< 2 L/min for 2 min
Water in circulation, one bay of six loops
about 75 gal
*My arithmetic from the spec values: 12.5 gal is 47 L, at 4 L/min. Not in the spec itself.
Rules that protect the loop
Low level stops that loop's pump. It must never run dry.
High level, or the bay leak sensor, closes all six fill valves and the rack master valve.
A fill valve closes after 10 minutes even if no switch trips. One fill at a time per rack.
A drain valve opens only with its fill valve closed. It closes at low level or after 12 minutes, and by itself on power loss.
No dosing unless the pump runs and flow reads above 2 L/min.
If the seated switch opens without a pull request, the pump stops and an alarm goes out.
Lab computer silent for 10 s: the bay PLC shuts fill and drain valves and cuts dosing, but keeps the pumps running.
Each pump has a hand-off-auto switch. Hand runs it straight from its fuse with every controller off.
Not proven yet
The four-way split. On the first pair, catch each nozzle in a cup for 30 s; all four should agree within 15 percent. A weak one has a longer, kinked or part-blocked tube. Do not pinch the others to match.
Pump watts at 4 L/min. Supplies and batteries assume 25 W. US price for the D5 is not quoted.
The 10 in pump gap between tank rows. Mock it up in cardboard first.
Splash. It can carry root pathogens a few inches. For a study that inoculates a loop, fit closed couplings on those cassettes.
Facilities answers: backflow preventer at the west tap, and whether solution and RO reject may go down the floor drain.