Work with usA part-by-part review of the Room 7551 design, the changes it needs, and what to buy and build. Plumbing, power and sensing are specified down to part numbers where a part could be checked.
Revision D follows the 17 November design meeting. Each cassette now has its own tank, pump, probes and dosing, so the lab holds 36 independent nutrient loops in place of 18. Light and air are still set per pair. The battery now carries the pumps for about 24 hours. Rows F20 to F24 list the additions.
Revision E, 18 November: each pair's light frame now moves up and down on a motor, and each pair can be blacked out. All control logic moves to one lab computer. Rows F25 to F27 list these.
Revision E.1, 24 November: the two fans of each pair now ride on the light frame, so the air stays just under the bars and above the canopy at every height. A moving cable loop carries their wires and the light leader (row B07b).
The layout, the pairing of cassettes, the three tiers and the zone plan all hold up. The problems sit in the details a builder meets first: pump head, couplings, wiring distance, access and safety. Each row says what this spec does about it.
| # | Part | What the design says | Problem | Change in this spec | Weight |
|---|---|---|---|---|---|
| F1 | Circulation pump | About 500 gal/h, 15 ft shut-off, $120, mains voltage | The pond pumps at that price stop at 11.6 to 13.5 ft. A tier 3 loop needs about 13 ft at the working flow. They cannot do it. | A 24 V wet-rotor pump with a published curve: about 14 L/min at 13 ft. Running at 24 V also puts the pumps on battery backup. | high |
| F2 | Dock coupling | Blind-mate non-spill coupling in the spine, $245 a set | The blind-mate coupling is plated brass, which the page itself bans from nutrient lines. The quarter-inch plastic size loses about 16 ft of head at the old design flow. | No coupling. Four fixed nozzles on the rack drop water into the channel inlets across a small air gap. Nothing touches the cassette, so it can be pulled automatically. Each cassette has its own pump, so stopping that pump isolates it. | high |
| F3 | Probe and dosing wiring | One controller per rack reads all probes and dosing pumps over I2C | I2C is a short-distance bus. Rack A would hang 84 devices on runs up to 14 ft. The maker warns against extended leads. | One small panel per bay. Wires stay under 4 ft. Each bay keeps running alone if the network stops. | high |
| F4 | Concentrate lines | Four lines run 40 ft overhead from the stock station to every bay | Two of them carry acid and base over people's heads on push-fit tube. All 72 pumps share four suction lines. | Jugs at each bay in a spill tray, under 3 ft from the pumps. The stock station becomes the mixing and refill point. Each bay can also run its own recipe. | high |
| F5 | Racks on casters | Racks stand free; safety factor 2.0 | The lift latches to the rack and the winch pulls about 50 lb on it. A rack on casters rolls. The 1 in 40 channel slope also needs a level frame. | Swap casters for levelling feet. Pull-test at 7 ft before use. Anchor if Facilities allows. | high |
| F6 | Room heat and moisture | $4,000 ventilation allowance | The lab will add about 7 kW of heat, and the plants about 120 to 200 pints of water a day at full load. Nobody has asked whether the room can take it. | Ask Facilities now. Fill the racks in stages and log room temperature and humidity as pairs come on. | high |
| F7 | Rack A light circuit | 12 drivers at 160 W on one 20 A circuit | That is the 16 A limit with no margin, and 160 W gives only about 175 to 200 µmol/m²/s. | Six listed 32 W bars per pair, 192 W. Three light circuits, six pairs each, 9.6 A. | medium |
| F8 | LED strips | Bare strips from an electronics distributor with separate drivers | Bare strips carry no wet rating and are not a listed fixture. Eighteen hand-built mains assemblies in a humid room will not pass a safety review. | Listed, IP66, plug-in bars with 0-10 V dimming. No listed bar fits the 41 in bay, so the bars run across the 5 ft 4 in depth. | medium |
| F9 | Bay fan | One fan per pair | One 110 CFM fan gives about half the air the page's own targets need: 2 °C rise and 0.3 m/s over the leaves. | Two fans per pair, side by side. Both racks draw from the middle aisle and blow outward. | medium |
| F10 | Tank access | Three tanks side by side across the rack depth | Nobody can reach the middle tank. pH probes need calibration and tanks need scrubbing. | Six narrow tanks per bay. Three face each aisle, so every tank has an end a person can reach. | medium |
| F11 | Reservoir | 30 × 18 × 12 in, $260 | That stock tank's cover is 34½ × 22½ in. Three will not fit a bay. | A 24 × 12 × 12 in tank, 15 gal, one per cassette. Three fit side by side on each face of a bay. | medium |
| F12 | Drain | 1½ in gravity header across the lift aisle under a ramp | A ramp over a 1½ in pipe stands about 3 in high. The lift should not roll over that. | The loop pump empties the tank through a ½ in line. That fits a 1¼ in high ramp rated for carts. Tanks no longer need stands. | medium |
| F13 | Fill valve | One solenoid per tank, with a time limit | A stuck valve can put a 275 gal tote on the floor. | A float valve after each solenoid, a master valve on each rack header, and a leak sensor that closes both. | medium |
| F14 | Flow and temperature sensing | Text mentions a flow sensor per cassette and a temperature probe | Neither is in the parts list or the signal count. | Both added: 36 flow sensors, 36 temperature probes. | medium |
| F15 | Lift price | $11,000 | The one reseller price found for this class of lift is $13,651. Another bundle is $24,690. | Allowance raised to $14,000. A hand-winch stacker with a custom deck is about $2,000. Rent or borrow before buying. | medium |
| F16 | Emergency stop | Cuts pumps, dosing and lights | Stopped pumps kill the crop within the hour if nobody resets. | The stop drops lights, filling and dosing. Pumps are 24 V and keep running. Every stop sends an alarm. | low |
| F17 | Vine and pot watering | Drip stakes from one small tank | The buckets have a feed but no return. Run-off would reach the robot floor. | A return gutter back to the vine tank is in the order list. The nine pots still need a watering decision. | low |
| F18 | Light between pairs | No wall between the two sides or between bays | Neighbouring pairs see each other's light. Day-length experiments would leak. | Each pair gets blinds and panels. See F26. | low |
| F19 | The page itself | Several sections still quote $162,000 and 3 ft racks. The parts list sums to $142,340. | Listed in section 16. | low | |
| F20 | Experimental unit | One tank per pair: 18 loops | The 17 November meeting asked for 36 to 48 experiments with replicates. Eighteen loops give six treatments in triplicate. | One loop per cassette: 36 tanks, pumps, probe sets and dosing sets. Twelve nutrient treatments in triplicate. Light and air stay per pair. | high |
| F21 | Power cuts | 12 Ah battery per supply, about 3 hours | The meeting asked for 12 to 24 hours. | One 24 V 100 Ah lithium iron phosphate battery per supply, in a floor cabinet at the dry end of each rack. About 24 hours with the pumps at 1 minute in 5. | high |
| F22 | Leaks between tiers | One drip tray under the tanks | A leak at tier 3 falls on the lights and plants of tier 2. | A drip pan under each tier 2 and tier 3 cassette, draining to that cassette's own return. | medium |
| F23 | Manual override | Pumps switch only through the PLC | A PLC fault stops the pumps, and nobody can start one by hand. | A hand-off-auto switch for each pump. Lights can be plugged straight into the outlet strip. | medium |
| F24 | Sensing near the roots | Probes in the tank only | The tank reading is mixed and delayed. New sensors have nowhere to go. | A plugged sensor port at each cassette's return collector. | low |
| F25 | Light height | Bars on chain, fixed at 15 in | Seedlings and tall crops need different distances. Tier 3 needs a ladder to change it. | Six bars on one frame per pair, raised and lowered by a tube motor on four cords. | medium |
| F26 | Blackout | Curtains later, by hand | Day-length treatments leak between pairs. | Motor blinds on both aisle faces of each pair, fixed panels on the bay sides, light-trap vents for air. | medium |
| F27 | Where the logic runs | Rules split between six PLCs and six bay computers | Six copies of every rule to write, test and keep in step. | One lab computer holds all logic. Bay hardware only reads inputs and sets outputs, with one watchdog rule. | medium |
Budget effect: this spec totals $205,623 against the page's $142,340 and the $175,000 cap. Dropping the couplings cost less. The second set of tanks, pumps, probes and dosing pumps adds about $23,000. The lights, the lift, the bay panels, the batteries and three more circuits also cost more. The 17 November meeting put the funding at $200,000. Revision E adds about $27,700 for the light lifts, the blackout, the motor units and the lab computer. The full list now passes $200,000. Section 12 gives the order to spend in, with blackout for the last 17 pairs at the end.
Label everything the same way on the hardware, in the wiring and in the data. Racks are A and B. Bays count from the west wall. Tiers count from the floor. A pair is one bay and tier: two cassettes that share a light frame and fans. A loop is one cassette with its own tank.
A1-T1 to B2-T3A1-T1-S, A1-T1-N| Tag | Device | Example |
|---|---|---|
| P | Circulation pump | P-A1-T3-S |
| FV, DV | Fill valve, drain valve | FV-A1-T3-S |
| LSL, LSH | Tank low and high level switch | LSL-A1-T3-S |
| HS | Hand-off-auto switch for the pump | HS-A1-T3-S |
| FT | Flow sensor, one per cassette | FT-A1-T3-S |
| PH, EC, TT | Probes in the tank | PH-A1-T3-S |
| DA, DB, DD, DU | Dosing pumps: A, B, pH down, pH up | DA-A1-T3-S |
| LT, FAN | Light group, fan pair | LT-A1-T3 |
| ZS | Cassette seated switch | ZS-A1-T3-N |
Thirty-six identical loops, one per cassette. Nothing is shared between loops except clean water in and waste out.
| Item | Head | Basis |
|---|---|---|
| Lift to the tier 3 channel inlet | 6.6 ft | From the design page |
| Suction valve, strainer, unions | 1.0 ft | Allowance |
| Riser, ½ in PVC, 15 ft with fittings | 0.2 ft | Calculated at 4 L/min |
| Flow sensor and the run to the nozzle rail | 0.5 ft | Allowance at 4 L/min |
| Coupling | 0 ft | Removed. The 0.5 to 1.2 ft it took is now spare margin |
| Four ¼ in tubes to the nozzles, 24 in each | 0.9 ft | Calculated at 1 L/min each |
| Margin | 1.5 ft | |
| Pump duty | 11 ft at 4 L/min | 3.4 m at 1.1 gal/min |
The chosen pump's curve shows about 14 L/min at 13 ft, so it has room and runs below full voltage. Tiers 1 and 2 need about 6 and 8 ft. Turn the pump voltage down on each loop until the cassette reads 4 L/min. Measure the watts there: the supplies and the battery assume 25 W.
The page used 1.5 L/min per channel. That figure suits channels many metres long. For a 32 in channel with four plants, 1 L/min is ample and cuts every pressure loss by half.
The nozzles must clear the cassette on its way out. Keep the tips above the caps and move the first plant site back an inch or two if leaves touch the rail. Splash can carry root pathogens a few inches. The collars, the walls between bays and the roof over each tier contain it. For a study that inoculates a loop, fit closed couplings on those cassettes.
A bay is the unit you build, test and repeat. It holds six tanks, six pumps, one panel, one dosing box and one tray of jugs. Six bays are loaded now.
Check that the bottom rails carry 700 lb per bay. If in doubt, stand the deck on its own feet on the floor.
Only one tank per rack fills at a time. The rack's fill meter then gives water use for that loop, which is the plants' uptake. That is 2 meters where 36 would be needed.
Source: the city's monthly data and 2026 water quality report. The water is lime softened. The report does not say whether the chlorine is free or combined. Call the plant and ask; combined chlorine needs a different carbon filter.
I recommend RO for a lab that compares nutrient recipes. Tap water at pH 9.5 with 145 ppm hardness would add its own minerals to every recipe and use pH down every day. The plant science leads should confirm.
576 plants take up roughly 15 to 25 gal a day at full size. That is my estimate from typical lettuce figures. One 275 gal tote covers more than a week. A full change of all 36 tanks is about 450 gal, so change a few each day.
Limits that never change with the recipe: no dose longer than 20 seconds, no more than 6 doses an hour per pump, and pH up and pH down never in the same 10 minutes. The PLC drops dose permit if the bay computer breaks these.
Weigh each pump's output before first use: run 30 seconds into a cup on a scale, three times. The maker gives ±1 percent, but tube length changes it.
The level assumes 80 percent of the light lands on plants. Measure it on the first pair: nine points per cassette with the PAR meter. Accept a mean of 200 or more, with the dimmest point at least 70 percent of the brightest. If it falls short, add a seventh bar.
Chosen parts. One motor type drives all 54: the Somfy Sonesse 30 DCT, 24 V, 2 Nm, reference 1241146. It takes plain up, down and stop contacts and sets its own end stops. Second choice: the Gaposa XS30 DC dry-contact motor, 2 Nm.
I found no ready-made light-tight blind this small with a wired 24 V motor. The motor price is from one US listing that shows a different reference number. Get a dealer quote. Buy one set for the first pair, then order the rest.
| Signal from the computer | What the part does by itself |
|---|---|
| Light frame up, light frame down | The tube motor winds or unwinds four cords. Its own end stops halt it at the top and bottom. |
| South blind up, down. North blind up, down | The motor in each roll runs to its own end stop. |
| Lights on or off, dim level | As before: one relay signal and one 0-10 V level per pair. |
| Reading back | From |
|---|---|
| Frame height | A distance sensor on the frame reads the gap to the cassette. |
| Frame at top | One switch. The computer uses it to zero the height. |
| Each blind closed | One switch at the bottom of each side channel. |
| Dark check | The pair light sensor must read dark with both blinds down and the neighbours lit. |
Open points: the light trap will cut airflow, and I have not sized that loss. The blind must clear the cassette grip bar and the dock bar. The cords must not shade the plants or foul the fans. Check all three on the first pair. The fans add about 2 to 3 lb with their plate and arms to the lift load (my estimate): weigh the frame with its fans before deciding on pulleys. With both blinds down the vent bands are the only air path, and the fans line up with them only when the frame is between about 10 and 16 in, near the top of its 17 in travel. Test dark-period airflow at the low and high limits on the first pair.
Facilities or a licensed electrician installs everything at mains voltage up to the outlets. Students plug listed equipment into those outlets and build only the 24 V side.
| Circuit, 120 V 20 A | Feeds | Load | Amps |
|---|---|---|---|
| L1 | Lights, bays A1 and A2 | 1.15 kW | 9.6 |
| L2 | Lights, bays A3 and A4 | 1.15 kW | 9.6 |
| L3 | Lights, bays B1 and B2 | 1.15 kW | 9.6 |
| C1 | Three 24 V supplies: pumps, fans, valves, panels | 1.2 kW | about 11 |
| W1 | Demand pump, RO, water-zone panel | 0.4 kW | 3 |
| S1 | Server cabinet | 0.5 kW | 4 |
| V1 | Two vine top lights | 1.3 kW | 11.7 |
| R1 | Robot docks, pot-row and vine side bars | not measured | |
| Rack and vine total | about 6.9 kW | ||
Each 24 V supply charges one battery and switches to it by itself. The supply tells the PLC when it is on battery. The PLC then turns the lights and fans off and runs each pump 1 minute in 5. That keeps the roots wet. Filling and dosing wait for mains power.
| On battery, per supply (two bays) | Watts |
|---|---|
| Twelve pumps at 25 W, on 1 minute in 5 | 60 |
| Two bay PLCs with relays and switches | 20 |
| Losses, 10 percent | 8 |
| Average load | 88 |
Battery: 24 V 100 Ah, 2.56 kWh. Using 90 percent gives 2.3 kWh, or about 26 hours at 88 W. Three batteries cover all 36 loops. The pump watts and the PLC load are estimates. Time the first pair on battery for four hours and scale. The bay computers run from the network switch, which has its own backup in the server cabinet.
| Module | Point | Signal |
|---|---|---|
| C2-14D2 in | X1 to X6 | Flow pulses: T1-S, T1-N, T2-S, T2-N, T3-S, T3-N |
| X7, X8 | Bay leak sensor; on-battery signal | |
| C2-14D2 out | Y1 to Y3 | Light relay box, T1 to T3 |
| Y4, Y5, Y6 | Dose permit relay; alarm beacon; spare | |
| C0-16ND3, first | 1 to 12 | Tank low and high level, six tanks |
| 13 to 16 | Emergency stop status; three spare | |
| C0-16ND3, second | 1 to 6 | Cassette seated, six |
| 7 to 12 | Pull request buttons, six | |
| 13 to 16 | "A pump switch is not in Auto"; three spare | |
| C0-08TR, first | 1 to 6 | Pumps, through 10 A relays; two spare |
| C0-08TR, second | 1 to 6 | Fill valves, through 10 A relays; two spare |
| C0-08TR, third | 1 to 6 | Drain valves, direct, 5 W each; two spare |
| C0-04DA-2 | 1 to 3 | Light dimming 0-10 V, T1 to T3; one spare |
| Motor unit C20, out | 1 to 18 | Per tier: light frame up, down; south blind up, down; north blind up, down |
| Motor unit C20, in | 1 to 9 | Per tier: frame at top; south blind closed; north blind closed |
One computer is one point of failure. Keep a second, identical computer on the shelf with the same program and a copy of the settings. The software for the lab computer does not exist yet.
| Device | T1-S | T1-N | T2-S | T2-N | T3-S | T3-N |
|---|---|---|---|---|---|---|
| pH circuit | 11 | 12 | 13 | 14 | 15 | 16 |
| EC circuit | 21 | 22 | 23 | 24 | 25 | 26 |
| Dosing A, B, down, up | 31 to 34 | 41 to 44 | 51 to 54 | 61 to 64 | 71 to 74 | 81 to 84 |
The pH and EC circuits ship at 99 and 100, and the pumps ship in serial mode at 103. Set each address once on the bench and write it on the part. Air sensors share fixed addresses, so they go through the multiplexer. Channels 0 to 2 carry each tier's south air sensor, light sensor and fan controller. Channels 3 to 5 carry the north air sensors. Channel 6 carries CO₂. One bay now has 36 devices on the main bus. Keep every lead short and prove the full bus on bay A1 before building the next bay.
cea/A1/T3/S/ph and cea/A1/T3/S/flow.| Where | Measures | Sensor | Count | Read by | Care |
|---|---|---|---|---|---|
| Each loop, 36 | |||||
| Tank | pH | Atlas lab pH probe, isolated circuit | 36 | Bay computer | Check against the handheld meter weekly. Recalibrate when it differs by 0.2. Keep wet. Life about 2.5 years. |
| Tank | Conductivity | Atlas K 1.0 probe, isolated circuit | 36 | Bay computer | Check weekly. Clean at crop change. |
| Tank | Solution temperature | DS18B20 stainless probe | 36 | Bay computer | Alarm above 25 °C. |
| Tank | Low and high level | Float switch | 72 | PLC | Lift by hand at crop change to test. |
| Each cassette feed | Flow | Hall pulse sensor, ½ in | 36 | PLC | Bucket-test each one once. |
| Each cassette return | Open port for a trial sensor | Plugged ¾ in port at the collector outlet | 36 | Bay computer | For reference probes and new sensors, next to the roots. |
| Each cassette | Seated | Reed switch and magnet | 36 | PLC | |
| Each cassette side | Air temperature, humidity | SHT41 | 36 | Bay computer | Shade from the bars. |
| Each pair | Light on, rough level | VEML7700 | 18 | Bay computer | Confirms the schedule ran. |
| Each pair | Fan speed | Tach line from the fans | 18 | Bay computer | Alarm on a stopped fan. |
| Each bay, 6 | |||||
| Drip tray | Leak | Point sensor, relay contact | 6 | PLC | Wet it to test at commissioning. |
| Mid height | CO₂ | SCD-41 | 6 | Bay computer | |
| Water zone and room | |||||
| Each rack header | Fill volume | Hall pulse sensor | 2 | Water-zone PLC | Gives water use per loop. |
| Totes | Low level | Float switch | 3 | Water-zone PLC | |
| Water-zone floor | Leak | Point sensor | 1 | Water-zone PLC | |
| Room, three points | Temperature, humidity | SHT41 on a bay computer or a wall logger | 3 | Bay computer | The lab list shows a Pulse Pro pending; it can serve. |
| Lab | Video | PoE cameras: lift aisle, rack aisle, pot grid | 3 | Edge PC | |
| Shared and handheld | |||||
| Any canopy | Light level | Apogee MQ-500 | 1 | Person | The lab list also shows an SQ-520 pending. |
| Any tank | pH and EC reference | Hanna HI9813-6N, already owned | 1 | Person | This meter is the reference for all 72 probes. |
| Any tank | Dissolved oxygen | Milwaukee MW600 | 1 | Person | Spot checks. |
| Any cassette | Images | Shared colour and near-infrared camera on a carriage | 1 | Edge PC | Carried from the design page. |
Not sensed, by choice: light spectrum, leaf temperature, and continuous tank level. Energy per circuit is worth adding once Facilities says which meter they accept; I could not confirm a listed one.
Sections 13 and 14. No money spent.
Tier 3 is the hardest case for the pump, the lift and the reach. Build it with water only first.
Facilities work, in parallel with step 2. A garden hose and one outlet are enough for the first pair.
Add tiers 1 and 2 to the same panel. Then build bays one at a time: A2, A3, A4, B1, B2. Log room temperature and humidity as each bay comes on. Stop adding bays if the room passes 26 °C or 75 percent humidity.
| Test | Pass |
|---|---|
| Run 24 hours on water | No drips anywhere. Drip tray dry. |
| Flow to each cassette | 4 L/min with the pump at or below 22 V |
| Flow from each of the 8 channels, cup and timer | Each within 15 percent of the mean |
| Film in the channel | Wet across the floor, no dry strip, no pooling |
| Tank temperature after 24 hours, lights on | No more than 3 °C above room |
| Pull and reseat each cassette 20 times with the pump running | Pump stops first; drips land in the catch, none on the tier below |
| Flow into each of the four channels | Within 15 percent of each other |
| Dye in one loop for a week | None in the partner cassette's tank or on the tier below |
| Pour 1 L into each drip pan | All of it reaches that cassette's own tank |
| Turn the PLC off, pump switch to Hand | Pump runs; alarm sent when the PLC returns |
| Fill: hold the solenoid open by hand | Float valve stops the water below the high switch |
| Fill: unplug the low switch | Pump stops within 2 seconds |
| Drain | Tank at low level in under 10 minutes |
| Each dosing pump, 30 seconds into a cup, 3 times | Within 3 percent of each other |
| Hold pH 5.8 and EC 1.5 for 48 hours | pH within 0.15, EC within 0.1 mS/cm |
| Light map, 9 points per cassette | Mean 200 µmol/m²/s or more; dimmest 70 percent of brightest |
| Air | Under 2 °C rise; 0.3 m/s at mid-canopy |
| Pull the plug on the 24 V supply for 4 hours | Pumps run 1 minute in 5; alarm sent; battery use projects to 24 hours or more |
| Unplug the bay's network cable for an hour | Safe state within 10 seconds; pumps keep running; alarm beacon on; normal control returns when the cable goes back |
| Run the frame from top to bottom 50 times | Stays level within 1/4 in end to end; stops at both ends every time |
| Read the frame height at five positions | Sensor within 1/2 in of a tape measure |
| Both blinds down, neighbours at full light | Under 0.1 µmol/m²/s at the canopy; no light line at any edge |
| Air with both blinds down | Flow at mid-canopy at least half of the open figure; humidity holds under the limit overnight |
| Pull a cassette with the blind down | The pull stays locked until the blind and frame are up |
| Pull a full cassette from tier 3 with the lift | One person, no spill, rack does not move |
| Push in and pull out each cassette 50 times | Latches by itself every time; one pull on the grip bar releases it |
| Pull on the frame with 50 lb, grip bar untouched | The cassette does not move |
Write the results in a sheet beside the order list. A failed test changes the order for the other seventeen pairs, which is why they wait.
The same list is in the spreadsheet with links and an order-status column. Price status: checked means the vendor page was open on 16 November. snippet means a search result only. allowance means my figure or one carried from the design page. Get a quote before trusting it.
Each phase ends with a lab that works. If the money stops, stop at the end of a phase.
| Phase | What you buy | Cost | Running total | If the money stops here |
|---|---|---|---|---|
| 1. One pair | Two cassettes at tier 3 of bay A1 with everything: loops, light lift, blinds, bay panel, lab computer. Rack rework, stairs and the light meter. | $17,572 | $17,572 | Two cassettes grow a crop under full control. Filled and drained by hose. Every design risk has been tested. |
| 2. Bay A1 | The other four loops and cassettes of bay A1. | $9,633 | $27,205 | Six independent loops. Enough for one small replicated trial. |
| 3. Water, drain and battery | Supply header, reverse osmosis, drain line, new circuits, three batteries, backflow preventer. | $20,238 | $47,443 | Bay A1 fills and drains itself and rides through a power cut. The room is ready for more bays. |
| 4. Rack A | Bays A2, A3 and A4 with their cassettes. | $49,761 | $97,204 | 24 loops on one rack. Four replicates of six treatments. |
| 5. Rack B | Bays B1 and B2 with their cassettes, and the spare pumps. | $33,694 | $130,898 | All 36 loops. The grow system is complete. |
| 6. Lift and instruments | Mast lift, pull winch, shared camera, reference meters. | $20,159 | $151,057 | One person can pull a tier 3 cassette. Until now that takes two people on the rolling stairs. |
| 7. The rest of the room | Robot lockers, cage, benches, cameras, server cabinet, vine bay. | $18,110 | $169,167 | The pot rows, the vine bay and the robot areas are fitted out. |
| 8. Blackout on the other 17 pairs | Blinds, panels, vents and switches for every pair after the first. | $16,456 | $185,623 | Any pair can run its own day length. Before this, only the first pair can. |
| 9. Reserves | Software and fabrication help, freight and tax, ventilation, design reserve. | $20,000 | $205,623 | Drawn on through every phase. Not a step to build. |
A $175,000 plan: phases 1 to 6 plus the full reserves, $171,057. It defers phase 7, the rest of the room ($18,110), and phase 8, blackout on the other 17 pairs ($16,456). The first pair keeps its blackout. The lab can use its present benches and storage until phase 7 is funded.
Phases 1 to 7 plus the reserves come to $189,167. Blackout on every pair takes the total to $205,623, which is over $200,000. With $200,000, blackout fits on about 11 more pairs if the reserves are fully spent. Phase 6 could move ahead of phase 5 if lifting at tier 3 by hand proves unsafe.
| Group | First pair | Full build |
|---|---|---|
| A. Nutrient loop (one per cassette) | $2,915 | $52,449 |
| B. Light and air (one set per pair) | $2,071 | $37,273 |
| C. Bay panel (one per bay of six loops) | $2,181 | $14,140 |
| D. Rack power, water zone and drain | $1,230 | $21,468 |
| E. Racks and cassettes | $756 | $18,630 |
| F. Handling and shared instruments | $1,600 | $22,953 |
| G. Lab zones | $0 | $12,900 |
| H. Vine bay | $0 | $5,210 |
| I. Services and reserves | $600 | $20,600 |
| Total, no contingency | $11,352 | $205,623 |
| Left under the $175,000 cap | $-30,623 | |
| Left under the $200,000 named at the 17 November meeting | $-5,623 (-3%) |
| ID | Item | Specification | Maker and part | Where | Each | First pair | Full | Full cost | Price |
|---|---|---|---|---|---|---|---|---|---|
| A. Nutrient loop (one per cassette) | $52,449 | ||||||||
| A01 | Reservoir tank, 15 gal | 24 x 12 x 12 in, polyethylene, internal flange. Works at 10 in depth, about 12.5 gal. Three stand side by side on each face of a bay. Wrap in black-and-white film. Part and size seen in a search result on 17 Nov. Price is my guess from the 22 gal tank ($134). | Tamco 6308 | U.S. Plastic | $105 | 2 | 36 | $3,780 | allowance |
| A02 | Tank cover | Loose cover for 6308. Drill for return, fill, probes, dosing, level switches. Sold separately. Price not opened. | Tamco 6358 | U.S. Plastic | $35 | 2 | 36 | $1,260 | allowance |
| A03 | Circulation pump, 24 V DC | Wet-rotor brushless, flooded suction. Must give 4 L/min at 11 ft (3.4 m). Published curve: about 14 L/min at 4 m, shut-off about 18 ft, 3 to 55 W. Curve verified, US price not. Four spares in the full count. Measure the watts at 4 L/min on the first cassette: the supplies and the battery are sized on 25 W. | Xylem / Laing D5 Strong, Noryl housing (D5-38/810N family) | Quote needed | $130 | 2 | 40 | $5,200 | allowance |
| A04 | Pump speed trim | DC-DC step-down module, 24 V in, 12 to 24 V out adjustable, 5 A. Sets flow by pump voltage. Set once per tier, then leave. | generic | Digi-Key / Amazon | $15 | 2 | 36 | $540 | allowance |
| A05 | Bulkhead fitting, 3/4 in | Polypropylene, EPDM gasket, 1-5/8 in hole. One for suction. | Banjo TF075 | U.S. Plastic / Dultmeier | $11 | 2 | 36 | $396 | snippet |
| A06 | Suction and discharge kit | 3/4 in PVC ball valve x2, union x2, inline strainer 50 mesh, tee for the drain branch, short hose No brass anywhere in nutrient lines. | generic | McMaster-Carr | $60 | 2 | 36 | $2,160 | allowance |
| A07 | Riser and return pipework | 1/2 in sch 40 PVC riser up the spine to the cassette, the cassette return trough, 1-1/2 in downpipe to its own tank, mesh sock on the return Two risers and two downpipes per pair. Nothing is shared. | generic | McMaster-Carr | $80 | 2 | 36 | $2,880 | allowance |
| A08 | No-contact feed nozzle set | Per cassette: rail bracket on the frame, four equal 1/4 in tubes ending in nozzles, four collars for the channel caps, one drip catch that drains to that cassette return. No coupling. Nothing touches the cassette. Prove the split between the four channels on the first pair. | generic | McMaster-Carr | $18 | 2 | 36 | $648 | allowance |
| A09 | Sensor port in the return collector | 3/4 in threaded port with a plug at each cassette collector outlet. A probe sits in the flowing return, next to the roots, for comparison with the tank probes. Added 17 Nov. Replaces the branch shut-off valve: each cassette has its own pump, so stopping the pump isolates it. | generic | McMaster-Carr | $12 | 2 | 36 | $432 | allowance |
| A09b | Drip pan under tier 2 and tier 3 cassettes | Lipped pan the size of the cassette, sloped to the spine, with a drain into that cassette own downpipe. Keeps a leak off the lights and plants below. Added 17 Nov. Tier 1 leaks land in the bay tray. | local fabrication | Local fabrication | $45 | 2 | 24 | $1,080 | allowance |
| A10 | Flow sensor, 1/2 in | Hall pulse, 1 to 30 L/min, food grade. One per cassette feed. Calibrate each by bucket test. Pulse constant differs between listings. | DIGITEN FL-408F | Amazon | $10.49 | 2 | 36 | $378 | snippet |
| A11 | Fill solenoid valve, 1/2 in, 24 V DC | Normally closed, zero differential, nylon body, EPDM. 20 W. Out of stock on 16 Nov. Stainless SZW-15-24VDC is $81.86. | ElectricSolenoidValves PSL-15 24 VDC | electricsolenoidvalves.com | $55.96 | 2 | 36 | $2,015 | checked |
| A12 | Float valve, 1/2 in | PVC, adjustable arm. Second shut-off after the solenoid. | Kerick MA052 | U.S. Plastic | $14.84 | 2 | 36 | $534 | checked |
| A13 | Drain valve, 3/4 in, motorised | 9 to 24 V, two-wire, closes by itself on power loss. Stainless, full port. On the pump discharge: the pump empties the tank. | U.S. Solid 3/4 in 2-wire auto return | ussolid.com | $30.31 | 2 | 36 | $1,091 | snippet |
| A14 | Level switch | Vertical polypropylene float, 1/8 in NPT. Two per tank: low and high. | Madison M8000 | PartsSource | $25.21 | 4 | 72 | $1,815 | checked |
| A15 | pH kit | EZO pH circuit, lab probe, isolated carrier board, calibration pouches $174.99 for one. Probe life about 2.5 years. | Atlas Scientific KIT-101P | Atlas Scientific | $161.99 | 2 | 36 | $5,832 | checked |
| A16 | Conductivity kit, K 1.0 | EZO EC circuit, K 1.0 probe, isolated carrier board, calibration pouches $259.99 for one. | Atlas Scientific EC-KIT-1.0 | Atlas Scientific | $240.50 | 2 | 36 | $8,658 | checked |
| A17 | Solution temperature probe | DS18B20, stainless, waterproof, 1 m lead. Read by the bay computer. The Atlas PT-1000 kit is analogue, not I2C, so it is not used. | generic DS18B20 | Adafruit / Digi-Key | $10 | 2 | 36 | $360 | allowance |
| A18 | Dosing pump | 0.5 to 105 mL/min, 12 to 24 V motor, I2C. Four per loop: A, B, pH down, pH up. 144 in the full build. Dropping pH up saves 36 of them. $94.99 for one. Ships in UART mode at address 103: set a unique I2C address on each. | Atlas Scientific EZO-PMP | Atlas Scientific | $87.99 | 8 | 144 | $12,671 | checked |
| A19 | Dosing tube and fittings | 5 mm OD tube, tank lid ports, labels in four colours | generic | McMaster-Carr | $20 | 2 | 36 | $720 | allowance |
| B. Light and air (one set per pair) | $37,273 | ||||||||
| B01 | LED grow bar, 4 ft, white | 32 W, 77 umol/s, 47.3 in long, 0-10 V dimming, IP66, UL 8800 wet location. Six per pair, across the rack depth, staggered. Spec sheet verified. Price is my guess until quoted. | GE Current Arize Lynk2 GEHL48HBRI3 | Distributor quote | $70 | 6 | 108 | $7,560 | allowance |
| B02 | Leader cable with dimming, 10 ft | One per pair. Up to 14 bars on one leader at 120 V. | GE Current GECA30A18-CC10B | Distributor quote | $35 | 1 | 18 | $630 | allowance |
| B03 | Jumper cable with dimming, 2 ft | Five per pair, bar to bar | GE Current GECA30A18-CF02B | Distributor quote | $10 | 5 | 90 | $900 | allowance |
| B04 | Plug-in relay for the lights | Cord-and-plug relay box switched by a 24 V signal. No mains wiring by students. Confirm the safety listing before buying 18. | Digital Loggers IoT Relay | Digi-Key / Amazon | $35 | 1 | 18 | $630 | allowance |
| B05 | Light frame | Two aluminium rails across the rack depth that carry the six bars as one frame, with four cord eyes Replaces the chain and S-hooks. | generic | McMaster-Carr | $40 | 1 | 18 | $720 | allowance |
| B12 | Light lift motor | 24 V DC tube motor, 2 Nm, 6 to 28 rpm, built-in electronic end stops, plain up, down, stop contacts. Fits a tube of 1.22 in bore or more. Rated IP30, so it sits under the drip pan, out of any drip. From 24 Nov the load includes the two fans and their bracket, about 2 to 3 lb more with the fan plate and arms (my estimate). One US listing at this price shows a different reference. Get a dealer quote. Second choice: Gaposa XS30 DC dry contact, 2 Nm. | Somfy Sonesse 30 DCT, ref 1241146 | Somfy dealer | $275.99 | 1 | 18 | $4,968 | snippet |
| B12b | Light lift shaft kit | 1.5 in aluminium tube across the rack depth, crown and drive for the motor, idler end, two brackets, four lift spools and lift ribbon Spool is $1.54. The rest is my estimate. | Rollease Acmeda CS4US spool and ribbon | AV Outlet | $60 | 1 | 18 | $1,080 | allowance |
| B13 | Frame height sensor and top switch | Time-of-flight distance sensor on the frame, read by the bay computer, and one reed switch at the top position | generic VL53L1X class | Adafruit / Digi-Key | $23 | 1 | 18 | $414 | allowance |
| B14 | Blind motor | Same motor as the light lift, so the lab stocks one spare type. One per aisle face. A 1 Nm motor would do this job for less. | Somfy Sonesse 30 DCT, ref 1241146 | Somfy dealer | $275.99 | 2 | 36 | $9,936 | snippet |
| B14b | Blackout blind kit | 1.5 in tube about 40 in long, blackout shade cloth with an 11 in drop, weighted hem bar, two brackets, and two aluminium U side channels for the posts My estimate. A shade shop can build the blind round the motor. | Phifer SheerWeave 7500 blackout cloth | AV Outlet or a local shade shop | $110 | 2 | 36 | $3,960 | allowance |
| B15 | Fixed blackout panels and seals | Black opaque sheet for the two bay sides and the upper band of both aisle faces, foam tape at every edge, brush seals round the pipes Top tier also needs a roof panel. | generic | McMaster-Carr | $90 | 1 | 18 | $1,620 | allowance |
| B16 | Light-trap vent | Black baffle that passes air and blocks light, the width of the bay. One in the vent band of each aisle face. The fans on the frame push air through them. Costs airflow. Test on the first pair. | generic darkroom louvre class | Photo or HVAC supplier | $45 | 2 | 36 | $1,620 | allowance |
| B17 | Blind closed switch | Sealed reed switch and magnet at the bottom of each side channel | generic | Digi-Key | $8 | 2 | 36 | $288 | allowance |
| B06 | Bay fan, 120 mm, 24 V | 110 CFM, IP67, PWM speed input and tach. Two per pair, side by side on the light frame at the middle-aisle edge. They ride up and down with the bars. PWM pin takes 5 V logic only. 24 V on that pin destroys the fan. | Noctua NF-F12 industrialPPC-24V-3000 SP IP67 PWM | Amazon | $34.95 | 2 | 36 | $1,258 | snippet |
| B07 | Fan guards and frame bracket | Wire guard both sides, and an aluminium bracket that bolts each fan under the light frame rail Changed 24 Nov: fans moved from a fixed plate to the light frame. | generic | Digi-Key | $15 | 2 | 36 | $540 | allowance |
| B07b | Moving cable loop | Coiled or festoon cable for the fans (power, speed, tach) and the light leader, so both follow the frame through 11 in of travel. One per pair. Added 24 Nov. Keep the loop clear of the cords and the fan intakes. | generic | Digi-Key | $25 | 1 | 18 | $450 | allowance |
| B08 | Fan speed controller | I2C fan controller with 25 kHz PWM and tach. One per pair. Prove on the first pair that the fans follow it. | Adafruit EMC2101 breakout | Adafruit | $6 | 1 | 18 | $108 | allowance |
| B09 | Air sensor, temperature and humidity | One per cassette side, shaded from the LEDs Out of stock on 16 Nov; SHT45 is $12.50. | Adafruit SHT41 (5776) | Adafruit | $5.95 | 2 | 36 | $214 | checked |
| B10 | Light sensor | Confirms lights on or off and rough level. One per pair. | Adafruit VEML7700 (4162) | Adafruit | $4.95 | 1 | 18 | $89 | checked |
| B11 | Cassette seated switch | Sealed reed switch and magnet. One per cassette. | generic | Digi-Key | $8 | 2 | 36 | $288 | allowance |
| C. Bay panel (one per bay of six loops) | $14,140 | ||||||||
| C01 | PLC CPU | Ethernet, Modbus TCP, MQTT, one option slot, 24 V DC | AutomationDirect C2-01CPU | AutomationDirect | $110 | 1 | 6 | $660 | checked |
| C02 | Option module, 8 fast inputs and 6 outputs | Counts the six flow sensors | AutomationDirect C2-14D2 | AutomationDirect | $66 | 1 | 6 | $396 | checked |
| C03 | Input module, 16 x 24 V DC | Level, leak, seated switches, pull buttons. Two per bay. | AutomationDirect C0-16ND3 | AutomationDirect | $69 | 2 | 12 | $828 | checked |
| C04 | Relay output module, 8 point | 1 A per point. Three per bay: pumps, fill valves, drain valves. Six modules on one CPU. Check the CLICK PLUS module limit and its 24 V budget before ordering. | AutomationDirect C0-08TR | AutomationDirect | $63 | 3 | 18 | $1,134 | checked |
| C05 | Analogue output module, 4 x 0-10 V | Dims three pairs of lights; one spare | AutomationDirect C0-04DA-2 | AutomationDirect | $175 | 1 | 6 | $1,050 | checked |
| C06 | Interposing relay and socket, 24 V coil, 10 A | For pumps and fill valves. Twelve per bay. | AutomationDirect 781 series | AutomationDirect | $15 | 4 | 72 | $1,080 | allowance |
| C07 | Bay computer | Raspberry Pi 4 Model B, 4 GB. Reads the probes and air sensors and passes dosing commands. Holds no rules. The lab list already has Pi 5 boards; the PoE+ HAT below fits Pi 4 only. | Raspberry Pi Pi 4 Model B 4GB | PiShop | $100 | 1 | 6 | $600 | checked |
| C08 | PoE+ HAT | Power and network on one cable | Raspberry Pi SC1022 | PiShop | $29.95 | 1 | 6 | $180 | checked |
| C09 | SD card, industrial, and DIN mount | 32 GB high-endurance card, DIN clip | generic | Digi-Key | $30 | 1 | 6 | $180 | allowance |
| C10 | I2C multiplexer | Eight channels. Separates sensors that share an address. Out of stock at Adafruit on 16 Nov. | Adafruit TCA9548A (2717) | Adafruit / Digi-Key | $6.95 | 1 | 6 | $42 | checked |
| C11 | Enclosure, 16 x 14 x 7 in | Polycarbonate, NEMA 4X, clear hinged cover | Integra H161407HCFLL | Solutions Direct | $220.33 | 1 | 6 | $1,322 | checked |
| C12 | Back panel, DIN rail, terminals, fuses, wire | Fused 24 V distribution, labelled terminals | generic ABP-1614 panel | AutomationDirect | $150 | 1 | 6 | $900 | allowance |
| C13 | Field connectors, M12 five-pin | About sixteen per bay, so a device swaps without rewiring | Murrelektronik 7000-12761-0000000 / 7000-12961-0000000 | AutomationDirect | $13.50 | 16 | 96 | $1,296 | checked |
| C14 | Dosing box | Second enclosure under the panel for the 24 dosing pumps, with a drip lip Keeps a split tube away from the electronics. | generic | Polycase / Integra | $120 | 1 | 6 | $720 | allowance |
| C15 | Bay stock jugs and tray | Two 2.5 gal jugs (A, B), two 1 gal jugs (pH down, pH up), one spill tray | generic | U.S. Plastic | $60 | 1 | 6 | $360 | allowance |
| C16 | Leak sensor, 24 V | Point sensor with relay contact, in the bay drip tray | GRI 2624 | Digi-Key / alarm supplier | $21.42 | 1 | 6 | $129 | snippet |
| C17 | Drip tray under the six tanks | Low tray or lined deck, 1 in lip | generic | U.S. Plastic | $60 | 1 | 6 | $360 | allowance |
| C18 | CO2 sensor | One per bay, read by the bay computer | Adafruit SCD-41 (5190) | Adafruit | $49.95 | 1 | 6 | $300 | checked |
| C19 | Hand-off-auto switch, one per pump | 22 mm three-position selector on a strip under the panel. Hand runs the pump without the PLC. Off stops it. Auto gives it back to the PLC. Added 17 Nov. A spare contact tells the PLC the switch is not in Auto. | generic | AutomationDirect | $14 | 2 | 36 | $504 | allowance |
| C20 | Motor input and output unit | Network I/O unit in its own small box: 18 contact outputs for nine motors (up, down) and 9 switch inputs. The lab computer drives it directly. The bay PLC has no free module slots for this. | generic part not chosen | AutomationDirect | $350 | 1 | 6 | $2,100 | allowance |
| D. Rack power, water zone and drain | $21,468 | ||||||||
| D01 | 24 V supply with battery backup, 20 A | DIN rail, 480 W, charges and switches to a battery by itself, Modbus status. One per two bays: two for rack A, one for rack B. Replaces the NDR-480 and the DR-UPS40. Before ordering, confirm in the data sheet that it has a lithium iron phosphate charge setting and what charge current it gives. Price not opened. | Mean Well DRS-480-24 | Digi-Key / Mouser | $230 | 1 | 3 | $690 | allowance |
| D02 | Backup battery, 24 V 100 Ah | Lithium iron phosphate, 2.56 kWh, built-in protection board, about 50 lb. One per supply. Buy a pack that carries a UL 1973 listing for the whole pack, not only its cells. Carries twelve loops at 1 minute in 5 for about 24 hours. Estimate: time it. | generic | Quote | $700 | 3 | $2,100 | allowance | |
| D03 | Battery cabinet | Steel floor cabinet, vented, lockable, on 4 in legs, at the dry east end of each rack. Rack A cabinet holds two batteries, rack B one. Not under the water header and at least 2 ft from a tank. | generic | Quote | $350 | 2 | $700 | allowance | |
| D03b | Battery disconnect and fuse | One DC-rated switch and one 40 A DC fuse at each battery, 8 AWG cable under 5 ft to the supply Have the electrician check the wire and fuse sizes. | generic | Quote | $60 | 3 | $180 | allowance | |
| D04 | Demand pump, 115 V | 3.3 gal/min, shuts off at 45 psi. Feeds the overhead header from the totes. Reuse the Barracuda transfer pump only for tote-to-tote moves. | Shurflo 2088-594-154 | Pump Agents | $180 | 1 | $180 | snippet | |
| D05 | Pressure regulator and gauge | Plastic, set to 20 psi, with a 0-60 psi gauge. One per rack header. | generic | McMaster-Carr | $45 | 2 | $90 | allowance | |
| D06 | Accumulator tank, 2 gal | Stops the demand pump from short-cycling. 1/2 in port. | generic | Quote | $60 | 1 | $60 | allowance | |
| D07 | Rack master fill valve | Same valve as A11, one per rack header. Opens only while a tank on that rack fills. | ElectricSolenoidValves PSL-15 24 VDC | electricsolenoidvalves.com | $55.96 | 2 | $112 | checked | |
| D08 | Rack fill meter | Same sensor as A10, one per rack header. One tank fills at a time, so this meters water use per loop. | DIGITEN FL-408F | Amazon | $10.49 | 2 | $21 | snippet | |
| D09 | Supply header and drops | 3/4 in PVC overhead with a shut-off and strainer per rack, 1/2 in drops | generic | McMaster-Carr | $450 | 1 | $450 | allowance | |
| D10 | Reverse osmosis unit | About 1,000 gal/day, with carbon prefilter and a float shut-off on the tote Needs 40 to 60 psi feed and a drain for the reject water. | Hydro-Logic Evolution RO1000 | Hydrobuilder / Hort supplier | $1,000 | 1 | $1,000 | snippet | |
| D11 | Tote level sensing | One low-level float switch per tote, wired to the water-zone inputs | Madison M8000 | PartsSource | $25.21 | 3 | $76 | checked | |
| D12 | Drain line and aisle cover | 1/2 in tube from each rack to the floor drain, under a 1-1/4 in high ramp Channel takes tube up to 0.75 in outside diameter. | Checkers Guard Dog GD1X75-B/B, two 36 in sections | Discount Ramps | $285.14 | 2 | $570 | snippet | |
| D13 | Drain tube and fittings | 1/2 in OD polyethylene, push-fit | John Guest PE-16 tube | SupplyHouse | $120 | 1 | $120 | snippet | |
| D14 | Stock drums, 15 gal | For mixing and storing A and B. Bay jugs are refilled from these. | U.S. Plastic 76680 | U.S. Plastic | $75.56 | 2 | $151 | checked | |
| D15 | Spill tray for the drums | Holds a full 15 gal drum | UltraTech 2328 | Grainger / Zoro | $189.99 | 1 | $190 | snippet | |
| D16 | Backflow preventer and connection | Supplied and fitted by Facilities at the west tap Their price, not mine. | Facilities | ISU Research Park / Facilities | $1,200 | 1 | $1,200 | allowance | |
| D17 | Emergency stop station | Twist to release, 1 NO + 1 NC | Schneider XALK178E | RSP Supply | $108.06 | 1 | $108 | checked | |
| D18 | PoE+ network switch, 24 port | 190 W PoE budget. In the server cabinet. | Netgear GS324TPv2 | Netgear | $249.99 | 1 | $250 | checked | |
| D19 | Network cable and outdoor-rated patch leads | Cat 6 to each bay panel and camera | generic | any | $300 | 1 | 1 | $300 | allowance |
| D22 | Lab control computer | Fanless small PC with two network ports and a solid-state drive, on the battery-backed supply. Holds all control logic. Buy two: one runs, one is the ready spare. Ask first whether the existing server can do this job. | generic part not chosen | any | $700 | 1 | 2 | $1,400 | allowance |
| D21 | Water-zone panel | One more PLC CPU (C2-01CPU) with a C2-14D2 option module, relays, a small enclosure and terminals. Runs the demand pump, the two master valves and the tote switches. Parts prices checked; the lot is my sum. | AutomationDirect C2-01CPU + C2-14D2 | AutomationDirect | $520 | 1 | $520 | allowance | |
| D20 | Circuits and installation | Eight 20 A 120 V circuits with ground-fault protection, cable tray, rack outlet strips, emergency stop wiring Was $9,000 for five circuits. | Facilities | ISU Facilities or an electrician | $11,000 | 1 | $11,000 | allowance | |
| E. Racks and cassettes | $18,630 | ||||||||
| E01 | Cassette | Carrier, lid, latch, guides, front door, four channel caps with a collared inlet hole at the high end. No plumbing on the cassette. 32 in long. Carried from the design page. | local fabrication | Local fabrication | $310 | 2 | 36 | $11,160 | allowance |
| E01b | Rotary latch, small, stainless | Push-to-close, single stage, with a release lever. Under the cassette front rail. Snaps shut round the striker when the cassette is pushed home. Added 17 Nov. Check the lever style against the drawing before buying 36. R4-10-21-105-20 has a rubber bumper, $33.95 at Zoro. | Southco R4-10-10-101-20 | Southco shop | $28.88 | 2 | 36 | $1,040 | snippet |
| E01d | Striker for the rotary latch | Small stainless striker on an angle bracket, bolted to the rack under the front rail at each slot. Price not seen. | Southco R4-90-101-20 | Southco shop | $8 | 2 | 36 | $288 | allowance |
| E01e | Grip bar kit | Per cassette: 1/2 in round stainless bar 4 in long, two 1/4 in shoulder screws as stems, four nylon flanged bearings, two return springs, and a 1/8 in link rod with clevises to the latch lever. The bar slides 1/2 in before it pulls the frame. | generic | McMaster-Carr | $17 | 2 | 36 | $612 | allowance |
| E01c | Hard stop and dock bar at each slot | On the rack: a rubber bumper at the spine end, and a 1/2 in round stainless dock bar on two stand-offs on the aisle face for the lift deck hooks. Added 17 Nov. Not priced before. | generic | McMaster-Carr | $14 | 2 | 36 | $504 | allowance |
| E02 | NFT channels and lids, reused | Cut from the existing channels. Allowance for shortfall. | reuse | CropKing | $1,800 | 1 | $1,800 | allowance | |
| E03 | Rack rework | Brackets, slide supports, fasteners to move the frames from six layers to three tiers | 80/20 | 80/20 / McMaster-Carr | $2,400 | 1 | $2,400 | allowance | |
| E04 | Levelling feet | Swap the casters for feet so the racks cannot roll and the channel slope holds Count the posts on site. | 80/20 2200 (1/2-13), check thread on site | Zoro / 80/20 | $34.42 | 24 | $826 | snippet | |
| F. Handling and shared instruments | $22,953 | ||||||||
| F01 | Mast lift | Raises a 65 lb cassette to 7 ft 3 in in a 4 ft 2 in aisle One reseller price seen: $13,651. A hand-winch stacker (Vestil A-LIFT-R-HP, $1,469) plus a custom deck is the low-cost route. | ServerLIFT SL-500FX | Reseller quote | $14,000 | 1 | $14,000 | snippet | |
| F02 | Pull winch | Hand strap winch on the mast | generic | McMaster-Carr | $300 | 1 | $300 | allowance | |
| F02b | Deck docking kit | On the lift deck: two hooks under the rack-side edge, slide strips 34.0 in apart, a spring catch with a release lever, and an end stop. Added 17 Nov. | local fabrication | Local fabrication | $200 | 1 | $200 | allowance | |
| F03 | Rolling stairs, 4 step | 40 in platform, handrails, 450 lb $348.99 plus $265 delivery. | Cotterman 1004R2630A3E10B3C2P6 | Zoro | $614 | 1 | $614 | snippet | |
| F04 | Shared camera on a carriage | Colour and near-infrared Carried from the design page. | Edmund Optics | $4,500 | 1 | $4,500 | allowance | ||
| F05 | PAR meter | Handheld | Apogee MQ-500 | Apogee | $580 | 1 | $580 | snippet | |
| F06 | Handheld pH and EC meter | The lab owns a Hanna HI9813-6N. Buy only if it is worn out. Already owned. | Hanna HI9814 | Hanna | $0 | 0 | $0 | snippet | |
| F07 | Handheld dissolved oxygen meter | Spot checks of root-zone oxygen | Milwaukee MW600 | TEquipment | $259 | 1 | $259 | snippet | |
| F08 | CO2, temperature and humidity reference | Mobile reference instrument Carried from the design page. | Vaisala | Vaisala | $900 | 1 | $900 | allowance | |
| F09 | Calibration solutions, storage solution, spare probes | pH 4, 7, 10 boxes; EC sets; two spare pH probes | Atlas Scientific ASPH4P-25, ASPH7P-25, ASPH10P-25, ASEC-K1.0, ENV-40-pH | Atlas Scientific | $1,600 | 1 | 1 | $1,600 | allowance |
| G. Lab zones | $12,900 | ||||||||
| G01 | Robot lockers | Two steel cabinets, entry room Carried from the design page. | see design page | $1,800 | 1 | $1,800 | allowance | ||
| G02 | Roll-in cage | Lockable wire cage Carried from the design page. | see design page | $1,500 | 1 | $1,500 | allowance | ||
| G03 | TV and wall mount | 65 in Carried from the design page. | see design page | $900 | 1 | $900 | allowance | ||
| G04 | Desks and benches | Use what the lab has first Carried from the design page. | see design page | $1,200 | 1 | $1,200 | allowance | ||
| G05 | Pots on the robot floor | Clamps and wiring; buckets, frame and bars reused Carried from the design page. | see design page | $600 | 1 | $600 | allowance | ||
| G08 | Lab camera screen and three cameras | Reolink RLC-520A class, PoE Carried from the design page. | see design page | $2,000 | 1 | $2,000 | allowance | ||
| G09 | Door with a glass panel | If Rick allows it Carried from the design page. | see design page | $800 | 1 | $800 | allowance | ||
| G10 | Floor tape and signs | Carried from the design page. | see design page | $300 | 1 | $300 | allowance | ||
| G11 | Healing bench | Carried from the design page. | see design page | $400 | 1 | $400 | allowance | ||
| G12 | Charging and docking bays | Three outlets on one circuit, floor marks Carried from the design page. | see design page | $900 | 1 | $900 | allowance | ||
| G13 | Server cabinet | Closed, filtered, with battery backup Carried from the design page. | see design page | $2,500 | 1 | $2,500 | allowance | ||
| H. Vine bay | $5,210 | ||||||||
| H01 | Strut channel, 1-5/8 in, 10 ft | About 240 ft: posts, doubled cross beams, rails Lengths over 10 ft need a splice or 20 ft stock: the beams are 11 ft. | Superstrut ZA1200HS-10 | Home Depot | $43.65 | 26 | $1,135 | snippet | |
| H02 | Strut fittings | Six post bases (P2072A), sixteen 45-degree braces (P1546), 90-degree plates (P1026), bolts and channel nuts | Unistrut P2072A, P1546, P1026 | Electrical supplier | $650 | 1 | $650 | snippet | |
| H03 | High-wire hooks with twine | Pack of 25, each holds 22 lb | Johnny's Rollerhook 7047 | Johnny's Selected Seeds | $35.30 | 1 | $35 | checked | |
| H04 | Drip stakes, 2 L/h | Pack of 25, pressure compensating | Netafim 01WPCJL2AW-24 | Hydrobuilder | $22.19 | 1 | $22 | snippet | |
| H05 | Vine irrigation set | One tank (6317 + 6367), one pump, timer output, supply line, return gutter from the ten buckets back to the tank Missing from the design page: the buckets had a feed but no return. | generic | U.S. Plastic / McMaster-Carr | $450 | 1 | $450 | allowance | |
| H06 | Top light for vines | About 650 W, 120 V, 5.8 A. Two fixtures. Spider Farmer SE7000 is $450 to $620 at 730 W. | HLG Scorpion Diablo | HLG | $1,299 | 2 | $2,598 | snippet | |
| H07 | Side bar hangers and cords | Sixteen adjustable wire hangers for the eight reused bars | generic | McMaster-Carr | $320 | 1 | $320 | allowance | |
| I. Services and reserves | $20,600 | ||||||||
| I01 | Ventilation and moisture allowance | Room air trim. A 210 pint/day dehumidifier (Anden A210V1, 240 V) is about $3,300 if the room needs it. | Facilities | $4,000 | 1 | $4,000 | allowance | ||
| I02 | Fabrication, software and commissioning | Carried. | $10,000 | 1 | $10,000 | allowance | |||
| I03 | Freight and tax reserve | Carried. | $3,000 | 1 | $3,000 | allowance | |||
| I04 | Hand tools and consumables | PVC cutter, primer and cement, crimp tools, ferrules, labels, heat shrink, bucket and scale for flow tests | any | $600 | 1 | 1 | $600 | allowance | |
| I05 | Design reserve | Carried. | $3,000 | 1 | $3,000 | allowance | |||
| # | Measure | Why it matters |
|---|---|---|
| 1 | Post spacing along each rack, and the clear gap between posts | Sets the bay width. Cassette width, bar count and tank layout all follow from it. The model's 41 in is an assumption. |
| 2 | Height of the bottom rails, and the clear height under where tier 1 will sit | Tanks are 12 in tall plus cover and fittings. They need about 18 in. |
| 3 | Frame profile size and the caster thread | Picks the levelling foot. Count the posts. |
| 4 | Ceiling height over the racks and the robot floor, to the lowest light, cord or sprinkler | The photos show the rack top at 8 ft 11 in. Tier 3 bars hang at about 9 ft. |
| 5 | Existing channel width, height and hole spacing | Sets cassette width and how many 32 in pieces you can cut. |
| 6 | Water pressure at the west tap, with a gauge | The RO unit needs 40 to 60 psi. |
| 7 | Where the lined trough at the west wall drains to | May remove the drain line across the aisle. |
| 8 | The building panel schedule, photographed with the door open | Spare breakers decide the electrical cost. |
| 9 | Wattage on the label of one existing LED tube, and a count | Sizes circuit R1 and the vine side lighting. |
| 10 | Weight of one existing rack, or of one post and one beam | Checks the tip-over figure and the deck load. |
| Zone | State of the design | What it still needs |
|---|---|---|
| Vine bay | Frame, loads and light hanging are worked out. The doubled beams match the maker's load table: 800 to 960 lb allowed over 10 to 12 ft, against 310 lb on the middle beam at the doubled design load. | Stock strut comes in 10 ft lengths and the beams are 11 ft. Buy 20 ft stock or shrink the frame to 10 ft. A fabricator's check. The return gutter. Ceiling height. |
| Pot grid, 9 pots | Layout and lighting set. | A watering method. Hand watering is fine to start. Saucers so no water reaches the robot lanes. |
| Mung rack | Kept where it is. No new design. | The 9 November mung module ($8,700) is not in this budget. Decide whether it is still wanted. |
| Saffron rack | Kept where it is. No new design. | The 9 November saffron module ($6,580) is not in this budget. The saffron grant may fund it. |
| Water zone | Specified in section 5. | A spill curb drawing. Tote stack stability: two full totes stacked weigh about 4,600 lb on one footprint. Confirm the stack is rated for it. |
| Lift and stairs | Method is sound. Rolling stairs chosen. | A lift quote. A deck 33 × 38 in is wider than the lift's 24 in base: have the deck checked for tipping. How a cassette goes back in at tier 3 is still open; a second strap anchor on the rack is the simplest answer. |
| Robotics corner and docks | Placed. One circuit. | Charger loads from the robot makers. |
| Server cabinet | Placed in the grow room, closed and filtered. | Facilities' answer. The entry room is the fallback. |
| Entry room, desks, benches, storage | Placed. | The door's clear width. |